Single-phase voltage stabilizer AMPERE-T U 16-1/32 v2.1
Single-phase voltage stabilizer Amper-T U 16-1/32 v2.1 (precise) is designed to operate in electrical networks with voltage fluctuations from 145 to 275V. In this range, the device is guaranteed to deliver a voltage at the output within 220 ± 2.7%, which is ensured through the use of 16 stabilization steps. The rated power of this model is 7 kW, which corresponds to an operating current of the circuit breaker of 32 A on it.
The features of this stabilizer include a double LED screen, a linear loading strip, the presence of electronic transit (bypass), a convenient location of the terminal block for connection on the back of the case, silent operation due to the use of triacs as power switches.
If it is necessary to obtain a voltage different from 220V at the output of the stabilizer in Ampere-T U 16-1/32 v2.1, there is a function for adjusting this value in the range of 200-230 V ± 2.7%.
The stabilizer Amper-T U 16-1/32 v2.1 has the ability to manually adjust the lower shutdown threshold (60-135V). This function is in demand for a load with high inrush currents, at startup of which a strong voltage drop and emergency shutdown of the stabilizer are possible. When this option is activated, the stabilizer will make it possible to start any engine or pump within a minute, even if the voltage drops to 60V in the network.
It is recommended to install and operate the Amper-T U 16-1/32 v2.1 stabilizer in dry and heated rooms. It is recommended to mount the wall in a vertical position (fans up), leaving 10-15 cm at the top and bottom for cooling. The connection is made to the existing wiring through the terminal block.
Operating current, A |
32 |
Rated power, kVA / kW |
7.0 |
Number of stabilization steps |
16 |
Key type |
triac |
The efficiency of the stabilizer is not lower,% |
98 |
Active power consumption at idle, no more, W |
35 |
Nominal output voltage, V |
220 |
Minimum operating input voltage, V |
100 |
Maximum input operating voltage, V |
295 |
Adjustment of the lower threshold of shutdown, V |
60-135 |
Output voltage regulation, V |
200-230 |
Accuracy in the stabilization range,% |
2.7 |
Response time to changes in input voltage, ms |
20 |
Power supply frequency, Hz |
45-65 |
Input Current and Apparent Power Measurement |
yes |
Short-circuit and overload current limitation |
input circuit breaker with B-characteristic electromagnetic protection |
Electronic Bypass |
yes |
Network and Stabilizer Condition Analyzer |
yes |
Duplicate overvoltage protection |
yes |
Microcontroller control |
yes |
Input choke |
yes |
Output choke |
no |
Overheating protection |
yes |
Minimum cable cross-section for connection, mm² |
6 |
Maximum cross-section of cable conductors for connection, mm² |
30 |
Forced Cooling |
two speed fan |
Overall dimensions, mm, no more |
460х275х165 |
Weight, kg, no more |
21 |
Warranty, years |
3 |
]]>